STAAD.Pro Help

D1.C.7 Code Checking and Member Selection

Both code checking and member selection options are available in STAAD LRFD implementation. See D1.B.1.3 Code Checking and D1.B.1.4 Member Selection for general information on these options.

Example for the LRFD-2001 code

UNIT KIP INCH
PARAMETER
CODE LRFD
FYLD 50 ALL
UNT 72 MEMBER 1 TO 10
UNB 72 MEMB 1 TO 10
MAIN 1.0 MEMB 17 20
SELECT MEMB 30 TO 40
CHECK CODE MEMB 1 TO 30

Example for the LRFD-1994 code

UNIT KIP INCH
PARAMETER
CODE LRFD2
FYLD 50 ALL
UNT 72 MEMBER 1 TO 10
UNB 72 MEMB 1 TO 10
MAIN 1.0 MEMB 17 20
SELECT MEMB 30 TO 40
CHECK CODE MEMB 1 TO 30